PEX-a and PEX-b are the same size and carry the same pressure rating. The letter is how the plastic is cross-linked. In SharkBite’s tubing, PEX-a bends tighter, a kink in Uponor’s PEX-a can be heated out, and expansion fittings are made for PEX-a. Crimp, clamp and push-to-connect fittings take either.
PEX-A and PEX-B side by side
| PEX-a | PEX-b | |
|---|---|---|
| How it’s cross-linked | Peroxide method | Silane method |
| Sizes sold | 1/2" to 2" | 1/4" to 1" |
| Outside of 1/2" pipe | 0.625" | 0.625" |
| Tightest bend radius, unsupported | 6 times the outside (3.75" on 1/2") | 8 times the outside (5" on 1/2") |
| Pressure rating | 160 psi at 73°F, 100 psi at 180°F | 160 psi at 73°F, 100 psi at 180°F |
| Colors | Red, white, blue | Red, white, blue |
From SharkBite’s spec sheets for its own PEX-a and PEX-b. Other brands publish their own figures.
Red, white and blue are colors, not types: SharkBite sells both kinds in all three. Every size has the same outside as copper tube, so 1/2" PEX of either kind is 0.625" across, the same as 1/2" copper. Inside and outside sizes for every size are on the PEX pipe size chart.
Fixing a kink
- Uponor PEX-a: a kink can be reformed. With the pressure off, straighten the pipe and heat the kink evenly with an electric heat gun to about 265°F until the pipe goes back to its shape, then let it cool untouched. Uponor says the pipe’s surface must never go over 338°F, and never to use a flame.
- SharkBite PEX: SharkBite’s PEX guide says not to heat a kink. Cut the kinked section out and join the ends with a coupling.
Crimp vs clamp vs expansion fittings
All three push a fitting into the pipe and lock it with a ring. They differ in the ring and the tool.

| Crimp | Clamp (cinch) | Expansion | |
|---|---|---|---|
| Standard | ASTM F1807 | ASTM F2098 | ASTM F1960 |
| Ring | Copper crimp ring | Stainless clamp ring with a tab | PEX ring over the pipe end |
| Tool | Crimp tool, one jaw per ring size | One clamp tool for every size | Expander tool |
| Check | Go/no-go gauge on each ring | Calibration gauge on the tool | Pipe and ring seat against the fitting’s shoulder |
| Pipe | PEX-a or PEX-b | PEX-a or PEX-b | PEX-a, per Watts and Uponor |
All three ASTM standards cover PEX tubing made to ASTM F876, which SharkBite’s PEX-a and PEX-b both meet. Makers still say what their own fittings take: Watts’ instructions for its LFFHB-1-PEX wall hydrant say its F1960 connection is for PEX-a tubing only, and Uponor’s ProPEX steps rely on the shape memory of Uponor’s own PEX-a.
- Crimp: slide the copper ring about 2" onto the pipe, push the pipe onto the barbed fitting up to its shoulder, and set the ring 1/8" to 1/4" from the pipe’s end so it sits over the barbs. Squeeze it with the crimp tool, then slide the gauge’s slot for that ring size onto it. The slot should slip on easily.
- Clamp: the same ring position, then squeeze the ring’s raised tab with the clamp tool. Check the tool with its calibration gauge before you start and after the last clamp, and the rings don’t need gauging one by one.
- Expansion: slide the ring onto the pipe end up to its stop edge, expand the pipe and ring with the tool, then push the fitting straight in. The pipe shrinks back onto the fitting. Uponor says to expand only as many times as needed: you should feel some resistance as the fitting goes in.
How to connect PEX to PEX
Use a coupling in the fitting system the pipe already has: a crimp or clamp coupling with two rings, or an expansion coupling on PEX-a. A push-to-connect coupling such as a SharkBite needs no ring or tool, and takes PEX of either kind, since both are made to ASTM F876. It also joins PEX to copper or CPVC: see PEX to copper.
Shut the water off and open a faucet to release the pressure before you cut into a PEX line.