A compression fitting seals with a nut and a brass sleeve (also called a ferrule or compression ring). Tightening the nut squeezes the sleeve onto the pipe and into the fitting. It’s sized by the outside of the tube, and BrassCraft’s compression stops take no tape.

Compression fitting sizes
A compression size is the tube’s outside, written “OD”. Copper pipe is sold by a nominal size that’s 1/8" smaller than its outside, so a fitting for 1/2" copper is marked 1/2" nominal or 5/8" OD. Measure the pipe’s outside before you buy.
| Marked | Tube outside | Where you see it |
|---|---|---|
| 1/4" OD | 1/4" | Ice maker water lines |
| 3/8" OD | 3/8" | The outlet of a shutoff valve, where a faucet or toilet supply line attaches |
| 1/2" nominal | 5/8" | The inlet of a shutoff valve on 1/2" copper |
| 3/4" nominal | 7/8" | Water heater connectors on 3/4" copper |
Nominal copper and its outside: Copper Tube Handbook (ASTM B88). Parts: BrassCraft’s angle stops, ice maker and water heater connectors.
How to install a compression fitting
These are BrassCraft’s steps for its compression shutoff valves. Other makers may give a different turn count, so follow the sheet that comes with yours.
- Shut off the water.
- Check the pipe end: cut square, round, and free of burrs.
- Slide the nut onto the pipe, then the sleeve.
- A drop of general purpose oil makes the nut easier to tighten.
- Seat the fitting on the pipe and tighten the nut by hand as far as it goes.
- Hold the fitting square to the pipe and turn the nut 3/4 turn more with a wrench.
BrassCraft says not to put thread seal tape, putty or gasket material on its compression stops. If you use a thread sealant, BrassCraft says to put a thin coat on the male threads only, never on the sleeve, because too much can make the joint fail.
On PEX
BrassCraft’s stops with a PEX compression inlet take PEX made to ASTM F876 or F877, with different parts: a plastic sleeve on 3/8" OD and smaller tube, and on anything larger a brass sleeve with a stainless steel insert pushed into the pipe end so it holds its shape.
Why a compression fitting leaks
- The fitting sits crooked on the pipe. BrassCraft notes a valve that isn’t square to the tube may not seal.
- The pipe end is rough or oval. A burr, a dent or a squashed end won’t seal under the sleeve.
- Tape or putty on the joint. BrassCraft’s stops take neither. Take it apart and clean it off.
- Too loose or too tight. Hand tight plus 3/4 turn is BrassCraft’s mark. Past that, BrassCraft warns that overtightening can crack the fitting and make it fail over time.
For a leak at a supply line nut rather than where the pipe enters the valve, see supply line leaking at the nut.
Compression vs SharkBite
| Compression | SharkBite push-to-connect | |
|---|---|---|
| Tools | A wrench | None to fit; a clip or tongs to take apart |
| Pipe | Type L or M copper; PEX on the PEX-inlet stops | Copper, PEX, CPVC, PE-RT, HDPE |
| Behind a wall | BrassCraft’s compression stops: accessible locations only | SharkBite’s end cap: approved behind walls with no access panel |
Compression: BrassCraft’s water supply stop instructions. Push-to-connect: SharkBite’s Max installation guide and end cap data sheet.
More on push-fit pipe, sizes and insertion depth is on SharkBite fittings.
Shut the water off before you loosen any compression nut, and keep a towel and bucket under the joint.